Views:

Product: LABELVIEW, CODESOFT
Version: All Network Versions


For versions 2012 and older:

1. Within the software, go to Tools and select Network Administration.

For versions 2014 and newer:

2. Open Network Administration from the Windows Start Menu.
Navigate to the TEKLYNX product folder (e.g., TEKLYNX CODESOFT 2025), expand it, and select Network Administration.

3. In the Network Administration window:
  • Check Use Network License
  • Verify the Server Location is correct (must begin with \\)
  • Click Modify to confirm the server appears in the list

If the server is not displayed:

4. Click OK, then close the software.
5. Navigate to the CS.ini file:
Windows XP:
C:\Documents and Settings\All Users\Application Data\Teklynx\[Product Name]
Windows 7 and newer:
C:\ProgramData\Teklynx\[Product Name]

6. Edit the file and update the following lines:
ServerName=\\servername
PathName=\TKDongle

7. Save and close the file.
8. Reopen the software and verify the connection.

If the issue persists, contact TEKLYNX Customer Support at 414-837-4800.