There are a few modifications that can be performed on the "TKXCS.xml" file to have SENTINEL act differently. The XML can be located "C:\Users\Public\Documents\Teklynx\Sentinel". The following edits will need to be placed under the General section.
<Lppa> int 5 (instances,1~100)
<Codesoft> int 14400 (seconds=4 hours)
<UseEngine> bool 1 (yes)
<UseCSEvents> bool 1 (yes)
<LasUser> string empty
<LasPassword> string empty
<LasHistoryMask> bit flag 12 ( Printing=1, Modifications=2, Errors=4, Warnings=8, Information=16)
<LasPathLab> string empty
<JobBuffering> bool 0 (no)
<RestartPE> bool 1 (yes, reboot PE on activeX error)
<MaxQuantity> long 2147483647 (this is max long value)
<OpenMergeDatabase> bool 0 (do not open database)
<LabelInfoVer> bool 1 (yes)
<ResetImg> bool 200 (after # images )
<RegisterClient> bool 1 (register on startup)
<TriggerForm> bool 0 (do not show filler)
<CloseLASLabels> bool 0 (keep open for next jobs)
<CloseLabelsOnTimer> int 300 (seconds=5 minutes)
|